產品標準本產品按GB12706《額定電壓35kV及以下銅芯、鋁芯塑料絕緣電力電纜》和GB12666《電線電纜燃燒實驗方法》標準生產,同時還可根據用戶需要按電工委員會*的IEC標準、英國BS標準、德國DIN標準、美國ICEA標準及日本JIS標準生產。 The product is manufactured according to the standard of GB12706 and GB12666 or IEC,BS,DIN,ICEA,and JIS upon request.
適用范圍本產品適用于工頻額定電壓0.6/1kV及以下配電線路或工業裝置中有耐火要求的固定敷設場所使用。 The product is suitable for use in power distribution lines or fixed installations with rated power-frequency voltage up to and including 0.6/1kV.
使用特性
·工頻額定電壓U0/U:0.6/1kV。 Rated power-frequency voltage U0/U:0.6/1kV.
·電纜導體的zui高允許*工作溫度(PVC/XLPE):70℃/90℃. Max.permissible continuous operating temperature of conductor (PVC/XLPE): 70℃/90℃
·短路時(zui長持續時間不超過5s)電纜導體zui高允許溫度 PVC:導體截面≤300mm2-160℃ 導體截面>300mm2-140℃ XLPE:250℃ Max.short-circuit temperature of the conductor shall not exceed(5s maxiumduration): PVC:cross-section of conductor≤300mm2-160℃ cross-section of conductor>300mm2-140℃ XLPE:250℃
·電纜敷設時環境溫度應不低于0℃ The ambient www.anhuidianlan.com under installation should not below 0℃
·電纜的彎曲半徑:多芯電纜不小于電纜外徑15倍,單芯電纜不小于電纜外徑20倍。 The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of multicore-cable should not less than 15 times of the cable diameter.
電纜的型號、名稱和用途 |
序 號 | 型 號 | 名 稱 | 使用范圍 | 1 | VV VLV VY VLY | 聚氯乙烯絕緣聚氯乙烯/聚乙烯護套電力電纜 | 敷設在室內、隧道及管道中,電纜不能承受機械外力作用 | VV22 VLV22 VV23 VLV23 | 聚氯乙烯絕緣聚氯乙烯/聚乙烯護套鋼帶鎧裝電力電纜 | 敷設在室內、隧道內直埋土壤,電纜能承受機械外力作用。 | VV32 VLV32 VV33 VLV33 VV42 VLV42 VV43 VLV43 | 聚氯乙烯絕緣聚氯乙烯/聚乙烯護套鋼絲鎧裝電力電纜 | 敷設在高落差地區,電纜能承受機械外力作用及相當的拉力。 | 2 | YJV YJLV YJY YJLY | 交聯聚乙烯絕緣聚氯乙烯/聚乙烯護套鋼帶鎧裝電力電纜 | 敷設在室內、隧道及管道中,電纜不能承受機械外力作用。 | YJV22 YJLV22 YJV23 YJLV23 | 交聯聚乙烯絕緣聚氯乙烯/聚乙烯護套鋼帶鎧裝電力電纜 | 敷設在室內、隧道內直埋土壤,電纜能承受機械外力作用。 | YJV32 YJLV32 YJV33 YJLV33 YJV42 YJLV42 YJV43 YJLV43 | 交聯聚乙烯絕緣聚氯乙烯/聚乙烯護套鋼絲鎧裝電力電纜 | 敷設在高落差地區,電纜能承受機械外力作用及相當的拉力。 | |