新能源汽車解決方案 水電計費方案 雙碳數智平臺 船舶岸電用能解決方案 工廠用能 源網荷儲 路燈漏電解決方案 配電室綜合監控系統 能源計量 預付費系統 工廠能耗 校園智慧能源管理平臺 儲能EMS系統 企業能源管控系統 光伏儲能系統 10KV配電站在線監測系統 路燈解決方案 能源物聯網平臺方案 EMS 軟件平臺 蓄電池在線監測系統 電能質量監測系統 汽車充電樁 分布式光伏解決方案 母線測溫解決方案 銀行安全用電 數采儀 電動自行車充電管理云平臺 5G基站能耗監測系統 智慧消防系統 重點用能企業能耗監測系統 智能照明系統 環保用電系統 能源管理系統 能耗管理系統 宿舍預付費系統 售電預付費系統 餐飲飲食油煙監測系統 電氣火災智慧安全用電 電力監控系統 電力運維云平臺
電能計量
中壓測控裝置
智能網關

Acrel anti-backflow meter apply in the Philippines photovoltaic project

時間:2022/1/8閱讀:564
分享:
1.Background
    With the development of photovoltaic industry, the capacity of village-level transformers and industrial power transformers and the installed capacity of photovoltaic projects are saturated in some areas.The power grid company requires the photovoltaic grid-connected system to be a non-backflow current generation system, which means that the electricity generated by the photovoltaic grid-connected system is consumed by the local load, and the excess electricity is not allowed to be sent to the upper power grid through the low-voltage distribution transformer in reverse direction.
    Photovoltaic inverter in photovoltaic components will produce direct current into alternating current (ac), has the dc component and harmonic mixing, unbalanced three phase current, output power of uncertainty, such as the current basic didn't take effective management measures, therefore, when there is power to the utility grid, will generate harmonic pollution to power network, easy cause power grid voltage fluctuation and flicker, etc.,If there are many such power sources to transmit electricity to the grid, the power quality of the grid will be seriously degraded.Therefore, this kind of photovoltaic power generation system must be equipped with anti-backflow current facilities to prevent the occurrence of reverse power.
    When the photovoltaic power generation is greater than the load demand, the inverse power will be generated.So we need instruments to determine that Inverter has power output, and then by the instrument through RS485 communication signal and inverter data interaction, adjust the inverter output power, so that its output power and power balance.
 
2.Project Overview
    A photovoltaic power generation company in the Philippines contacted our company to look for anti-backflow current meters. After proper connection agreement, we will purchase ACR10R-D16TE from our company.

3.Anti-backflow detection meter
    When the photovoltaic power generation is greater than the load demand, reverse power will be generated. Therefore, we need an meter to determine that the inverter has over-power output, and then the meter sends a signal through RS485 communication to interact with the inverter data to adjust the output power of the inverter to balance the output power and the electrical power.
4.Function 
 
 

5.Wiring
 